Dépôt DSpace/Manakin

The role of ultrasound-guided tru-cut biopsy in ovarian cancer: a systematic review of its safety, adequacy, and accuracy with meta-analysis of diagnostic performance

Afficher la notice abrégée

dc.rights.license CC BY eng
dc.contributor.author Ndukwe, Munachiso Iheme cze
dc.contributor.author Pavone, Matteo cze
dc.contributor.author Habes, Dominik cze
dc.contributor.author Bizzarri, Nicolo cze
dc.contributor.author Stepan, Martin cze
dc.contributor.author Bretova, Petra cze
dc.contributor.author Mascilini, Floriana cze
dc.contributor.author Karasek, Dominik cze
dc.contributor.author Pohankova, Denisa cze
dc.contributor.author Ubom, Akaninyene cze
dc.contributor.author Havigerová, Jana Marie cze
dc.contributor.author Haviger, Jiří cze
dc.contributor.author Sirak, Igor cze
dc.date.accessioned 2025-12-05T16:07:57Z
dc.date.available 2025-12-05T16:07:57Z
dc.date.issued 2025 eng
dc.identifier.issn 1757-2215 eng
dc.identifier.uri http://hdl.handle.net/20.500.12603/2446
dc.description.abstract ObjectivesTo analyze the safety, adequacy and accuracy of ultrasound-guided tru-cut biopsy in the diagnosis of ovarian cancer.MethodsA systematic search of PubMed, Web of Science, and Scopus was conducted through June 2024. Studies meeting predefined criteria were included in the review. The quality of diagnostic accuracy studies was assessed using QUADAS-2. A meta-analysis was performed on studies reporting complete 2 x 2 diagnostic data.ResultsA total of 2,250 articles were initially screened, and after the removal of duplicates, 54 articles were deemed eligible for full-text assessment. Ultimately, 18 studies, comprising 1,867 patients who underwent ultrasound-guided tru-cut biopsy, were included in the systematic review. A total of 16 complications were reported across 1,898 biopsies performed in the included studies, resulting in a mean complication rate of 0.58% (95% CI: 0.187- 0.964%). Adequacy for histological and immunohistochemical examination after one attempt was reported in 16 studies, with a mean adequacy rate of 95.1% (95% CI: 92.69- 97.50%) and a median rate of 95.97%. Diagnostic accuracy was assessed in 13 studies, revealing a mean diagnostic accuracy of 95.54% (95% CI: 93.19- 97.89%) and a median of 97.48%.In the meta-analysis of 10 studies, pooled sensitivity was 98.6%, specificity 41.9%, positive predictive value (PPV) 99.0%, and negative predictive value (NPV) 47.2%, with high heterogeneity observed in specificity and NPV estimates.ConclusionsUltrasound guided tru-cut biopsy is a safe and effective diagnostic method, demonstrating a high adequacy rate for histological and immunohistochemical analysis. It shows excellent performance in confirming malignancy and supports preoperative decision making. To further define its role in the diagnostic pathway for ovarian cancer, additional prospective multicenter studies are needed-both to validate its reliability in negative cases and to ensure tissue adequacy for advanced molecular testing in the context of personalized medicine. eng
dc.format p. "Article number: 166" eng
dc.language.iso eng eng
dc.publisher BMC eng
dc.relation.ispartof JOURNAL OF OVARIAN RESEARCH, volume 18, issue: 1 eng
dc.subject Ovarian cancer eng
dc.subject Ultrasound eng
dc.subject Tru-cut biopsy eng
dc.subject Core needle biopsy eng
dc.subject Systematic review eng
dc.title The role of ultrasound-guided tru-cut biopsy in ovarian cancer: a systematic review of its safety, adequacy, and accuracy with meta-analysis of diagnostic performance eng
dc.type article eng
dc.identifier.obd 43882181 eng
dc.identifier.wos 001538764800003 eng
dc.identifier.doi 10.1186/s13048-025-01739-7 eng
dc.publicationstatus postprint eng
dc.peerreviewed yes eng
dc.source.url https://ovarianresearch.biomedcentral.com/articles/10.1186/s13048-025-01739-7 cze
dc.relation.publisherversion https://ovarianresearch.biomedcentral.com/articles/10.1186/s13048-025-01739-7 eng
dc.rights.access Open Access eng


Fichier(s) constituant ce document

Ce document figure dans la(les) collection(s) suivante(s)

Afficher la notice abrégée

Chercher dans le dépôt


Parcourir

Mon compte