<link rel="stylesheet" href="styles.cf390c6bfbe7555f.css">

A Novel Fault Detection and Location Approach for DC Zonal Shipboard Microgrid Based on High-Frequency Impedance Estimation With IEC 61850 Communication Protocol

dc.contributor.authorAboelezz, Asmaa M
dc.contributor.authorEl-Saadawi, Magdi M
dc.contributor.authorEladl, Abdelfattah A
dc.contributor.authorBureš, Vladimír
dc.contributor.authorSedhom, Bishoy E
dc.date.accessioned2025-12-05T14:43:16Z
dc.date.available2025-12-05T14:43:16Z
dc.date.issued2024
dc.description.abstractThis paper introduces an innovative adaptive scheme for detecting and locating faults in DC-zonal shipboard microgrids (SBMGs). This scheme relies on the estimation of high-frequency impedance. The proposed scheme is implemented in an intelligent electronic device (IED) in which the Fast Fourier Transform is applied to obtain the high-frequency components of the current and voltage at each node. Then, these components are exchanged between the two IEDs that protect the same line by using IEC 61850 GOOSE-based communication system. The estimated high-frequency impedance of the line is calculated and compared to the prescribed settings to detect and locate the fault. After fault detection and localization, communication signals are exchanged between the two IEDs positioned at each end of the line. This exchange precedes the transmission of tripping signals to the relevant circuit breakers for the accurate isolation of the faulty line. The proposed protection scheme is tested through MATLAB/Simulink (R) environment. The scheme can detect and locate the fault under different uncertainty conditions, such as fault impedances, various system configurations, changes in system loads and generations, multi-faults' existence, contingency conditions, and the presence of noise on the communication signals. The results proved its efficient performance and superiority. The scheme can detect and locate the faults quickly and accurately within 0.125 ms.eng
dc.formatp. 36212-36228
dc.identifier.doi10.1109/ACCESS.2024.3374198
dc.identifier.issn2169-3536
dc.identifier.obd43881360
dc.identifier.urihttp://hdl.handle.net/20.500.12603/2203
dc.identifier.wos001184231200001
dc.language.isoeng
dc.peerreviewedyes
dc.publicationstatuspostprint
dc.publisherIEEE
dc.relation.ispartofIEEE Access, volume 12, issue: Marcheng
dc.relation.publisherversionhttps://ieeexplore.ieee.org/document/10460547
dc.rights.accessOpen Access
dc.rights.licenseCC BY
dc.source.urlhttps://ieeexplore.ieee.org/document/10460547
dc.subjectDC zonal shipboard microgrideng
dc.subjectfault detectioneng
dc.subjectfault localizationeng
dc.subjecthigh-frequency impedance estimationeng
dc.subjectIEC 61850eng
dc.subjectNovel protection schemeeng
dc.titleA Novel Fault Detection and Location Approach for DC Zonal Shipboard Microgrid Based on High-Frequency Impedance Estimation With IEC 61850 Communication Protocoleng
dc.typearticle

Soubory

Původní svazek

Nyní se zobrazuje 1 - 1 z 1
Načítá se...
Náhled
Název:
A_Novel_Fault_Detection_and_Location_Approach_for_DC_Zonal_Shipboard_Microgrid_Based_on_High-Frequency_Impedance_Estimation_With_IEC_61850_Communication_Protocol.pdf
Velikost:
3,23 MB
Formát:
Adobe Portable Document Format