<link rel="stylesheet" href="styles.cf390c6bfbe7555f.css">

Multi-Biometric System Based on Cutting-Edge Equipment for Experimental Contactless Verification

dc.contributor.authorKolda, Lukáš
dc.contributor.authorKrejcar, Ondřej
dc.contributor.authorSelamat, Ali Bin
dc.contributor.authorKuča, Kamil
dc.date.accessioned2020-06-01T11:05:20Z
dc.date.available2020-06-01T11:05:20Z
dc.date.issued2019
dc.description.abstractBiometric verification methods have gained significant popularity in recent times, which has brought about their extensive usage. In light of theoretical evidence surrounding the development of biometric verification, we proposed an experimental multi-biometric system for laboratory testing. First, the proposed system was designed such that it was able to identify and verify a user through the hand contour, and blood flow (blood stream) at the upper part of the hand. Next, we detailed the hard and software solutions for the system. A total of 40 subjects agreed to be a part of data generation team, which produced 280 hand images. The core of this paper lies in evaluating individual metrics, which are functions of frequency comparison of the double type faults with the EER (Equal Error Rate) values. The lowest value was measured for the case of the modified Hausdorff distance metric - Maximally Helicity Violating (MHV). Furthermore, for the verified biometric characteristics (Hamming distance and MHV), appropriate and suitable metrics have been proposed and experimented to optimize system precision. Thus, the EER value for the designed multi-biometric system in the context of this work was found to be 5%, which proves that metrics consolidation increases the precision of the multi-biometric system. Algorithms used for the proposed multi-biometric device shows that the individual metrics exhibit significant accuracy but perform better on consolidation, with a few shortcomings.eng
dc.description.abstract-translatedBiometric verification methods have gained significant popularity in recent times, which has brought about their extensive usage. In light of theoretical evidence surrounding the development of biometric verification, we proposed an experimental multi-biometric system for laboratory testing. First, the proposed system was designed such that it was able to identify and verify a user through the hand contour, and blood flow (blood stream) at the upper part of the hand. Next, we detailed the hard and software solutions for the system. A total of 40 subjects agreed to be a part of data generation team, which produced 280 hand images. The core of this paper lies in evaluating individual metrics, which are functions of frequency comparison of the double type faults with the EER (Equal Error Rate) values. The lowest value was measured for the case of the modified Hausdorff distance metric - Maximally Helicity Violating (MHV). Furthermore, for the verified biometric characteristics (Hamming distance and MHV), appropriate and suitable metrics have been proposed and experimented to optimize system precision. Thus, the EER value for the designed multi-biometric system in the context of this work was found to be 5%, which proves that metrics consolidation increases the precision of the multi-biometric system. Algorithms used for the proposed multi-biometric device shows that the individual metrics exhibit significant accuracy but perform better on consolidation, with a few shortcomings.cze
dc.formatArticle number 3709
dc.identifier.doi10.3390/s19173709
dc.identifier.issn1424-8220
dc.identifier.obd43875479
dc.identifier.urihttp://hdl.handle.net/20.500.12603/311
dc.identifier.wos000486861900079
dc.language.isoeng
dc.peerreviewedyes
dc.publicationstatuspostprint
dc.publisherMDPI
dc.relation.ispartofSENSORS, volume 19, issue: 17eng
dc.relation.publisherversionhttps://www.mdpi.com/1424-8220/19/17/3709
dc.rights.accessOpen Access
dc.rights.licenseCC BY
dc.source.urlhttps://www.mdpi.com/1424-8220/19/17/3709
dc.subjectbiometryeng
dc.subjectidentificationeng
dc.subjectbloodstreameng
dc.subjectimage recognitioneng
dc.subjectmulti-biometricseng
dc.subjectbiometriecze
dc.subjectidentifikacecze
dc.subjectkrevní oběhcze
dc.subjectrozpoznávání obrazucze
dc.subjectmulti-biometriecze
dc.titleMulti-Biometric System Based on Cutting-Edge Equipment for Experimental Contactless Verificationeng
dc.title.alternativeMulti-biometrický systém založený na řezném okraji pro experimentální bezkontaktní ověřenícze
dc.typearticle